Is there any difference between a magnetic lock and an electric lock?
Release time:2023-03-16

The magnetic lock has no mechanical bolt structure, and its strong "suction" completely attracts the door leaf to achieve the purpose of locking. When "access control" is necessary for frequent access, electromagnetic locks are the most durable, sturdy and safe electric locks!


The electric mortise lock is an electronically controlled lock, which drives the extension or retraction of the "bolt" through the on and off of the current to achieve the function of locking or opening the door. Generally, an electric bolt lock is composed of two main parts: a lock body and a keyhole. The key component in the lock body is the "lock tongue", which can be combined with the "lock hole" to realize the two states of "closed" and "opened". That is, the lock tongue is inserted into the lock hole to close the door, and the lock tongue leaves the lock hole to open the door. Because of the retractable function of the bolt, it was given the name "electric bolt lock". It is precisely because of this feature that electric mortise locks are often used on various swing doors (two-way opening). At the same time, its "hidden" installation feature is more suitable for places with higher requirements on the confidentiality of the lock body.


The working principle of the magnetic lock is the same as that of the electromagnet. It uses electricity to generate magnetism, and then the opposite poles attract each other. When the current passes through the silicon steel sheet, the electromagnetic lock will produce a strong suction force and tightly attract the adsorption iron plate to lock the door. effect. As long as a small current electromagnetic lock will produce a huge magnetic force, the access control system that controls the power supply of the electromagnetic lock will cut off the power after identifying the correct personnel, and the electromagnetic lock can open the door after it loses its suction. Because the electromagnetic lock has no complicated mechanical structure and the structure of the bolt, it is suitable for the passage control of the escape door or the fire door. The lock body is protected by pouring epoxy resin inside. At present, the suction strength of electromagnetic locks is expressed in LB (pounds), and the test method is static pressure.


The so-called static pressure means that the electromagnetic lock gradually increases the pulling force on the adsorption iron plate after the electromagnetic lock is energized. When the suction force of the electromagnetic lock is exceeded, the adsorption iron plate is pulled open instantly. The data of this tensile force is the tensile force value of the electromagnetic lock. Moreover, the force of the electromagnetic lock and the adsorption iron plate must be face to face and linear pressure, so that the electromagnetic lock has the greatest suction force. The adsorption iron plate may be temporarily magnetized due to the magnetic induction of the electromagnet for a long time.


The signal output transmission between the placket card and the magnetic lock and the electric mortise lock. Usually the signal transmission method between them is through RS422, RS485, RS232 several commonly used data transmission methods, among which RS422 is a duplex data transmission method. Transmitted to the outside. The transmitted data is generally in odd numbers. Three-wire and five-wire signal lines are used for more wiring, and are used for signal induction with magnetic locks or electric bolt locks in the placket system. RS485 communication converter. It is a double and a half singular data transmission signal. His characteristic is that there is less wiring. The transmission distance is long and the magnetic lock or electric bolt lock connected with it should not be too many. If there are too many, it must be divided into multiple interfaces without management.


But relatively speaking, the agreement will be more complicated. They are generally used in the doorway of the intercom of the building. Magnetic locks or electric bolt locks transmit signals. RS323 communication converter is used in smart devices. It is characterized by short transmission distance. Nowadays, the application of smart devices in the community is relatively common. So its application is also the most extensive.


Subscribe
Please continue to read, keep posting, subscribe, we welcome you to tell us your thoughts.
Contact us

Shenzhen Weimai Intelligent Technology Co., Ltd.

Address: Room 301, Building A3, No. 1, Qimeng Wisdom Park, No. 28, Youtian Road, Anliang Community, Yuanshan Street, Longgang District, Shenzhen

Zip code: 518115

Phone: 13590330491 18500138588

Corporate media

  • WeChat official account

  • Mobile website
Copyright © 2021 Shenzhen Weimai Intelligent Technology Co., Ltd. All rights reserved 粤ICP备2021036547号